DAF + MBBR

Dissolved air flotation as an upstream step to remove fats, oils and fine solids before the MBBR.

In industrial applications where the wastewater carries significant fats, oils, grease (FOG) or fine suspended solids that do not settle well, a dissolved air flotation (DAF) unit upstream of the MBBR is often the most effective pretreatment. DAF injects micro-bubbles that attach to particles and float them to the surface for removal, protecting carriers and biofilm from coating and clogging.

Why DAF suits MBBR pretreatment

FOG and fine colloidal solids are not removed effectively by gravity sedimentation but are lifted efficiently by DAF. Removing them upstream protects the carrier surface from coating (which reduces active biofilm area), prevents grease from accumulating on retention screens and reduces the total organic load reaching the biological stage. For food, dairy, meat-processing and similar industries, DAF + MBBR is a proven and compact combination.

DAF units are typically dosed with coagulant and/or polymer to aggregate the fine particles before flotation. The floated sludge (float) is high in organic matter and must be handled separately. The clarified underflow feeds the MBBR at a much lower FOG and TSS concentration, which lets the biofilm develop on clean carrier surfaces.

DAF pretreatment design

DAF + MBBR design factors (indicative — confirm per project)

ParameterTypical ValueUnitNotes
Target removalFOG + fine TSS—Protects carriers and screens.
ChemistryCoagulant ± polymer—Aggregates fine particles for flotation.
Float handlingHigh-strength waste—Must be managed separately.
IndustriesFood, dairy, meat, etc.—Where FOG is significant.

Frequently Asked Questions

When is DAF needed before an MBBR?
Whenever the wastewater contains significant fats, oils, grease or fine colloidal solids that gravity settling cannot remove. This is common in food, dairy, meat, beverage and similar industrial effluents.
Can the MBBR work without DAF pretreatment?
If FOG levels are low and the wastewater is mostly dissolved organics, DAF may not be needed. However, if grease coats the carriers it smothers the biofilm and reduces treatment capacity, so the decision should be based on the actual wastewater characteristics.
Does DAF reduce the MBBR size?
Yes, because it removes a fraction of the organic load (especially particulate and colloidal COD) and all of the FOG, so the biological stage sees a cleaner, lower-loaded feed and can be sized smaller.

Related Pages

Need MBBR Design Support?

Submit your wastewater data for a preliminary MBBR engineering assessment. Our team reviews every submission within 2 business days.

Start MBBR Assessment